Versa Controls
HIGH VOLTAGE_HIGH-CURRENT PROBES




Click image to zoom

Product Information:

Features
  • PROBES are set to place the shunt directly into the measuring circuit
  • Without measuring circuit protection
Current measurement
  • Protection of the measuring circuit has to be provided by the user
Construction
  • Shunt (type BF1 or BF2) with mounting straps (temperature range -40...+130°C)
  • Memory device used for PROBE-identification and calibration data (placed in connector)
  • Data cable = L2 (1...5 m) with 8-pin Redel connector
circuit diagram

Caution: The maximum continuous current is lower than the measuring range. Please refer to the user manual.

  • TYPE BF1


     

    • Resistor [mΩ] Measuring range [A] Resolution/Bit* [mA] Maximum permanent current** [A]
      2 -150…360 0,125 60
      1 -300…+720 0,25 80
      0,5 -600…+1440 0,5 120
      0,2 -1500…+3600 1,25 150

      size (l/w/h): 42x16x15 mm
      the shunts are linked with a copper bar 20x3x200 mm
      * indicated for the lowest measuring range
      ** at room temperature (23°C)

    Order code

    <name> - <resistance value> - <L1> - <L2> - <L3>

    name resistance value L1 L2 L3
    HV-I-BF1 2/…/0,2 0 1…5 0
  • TYPE BF2


     

    • Resistor [mΩ] Measuring range [A] Resolution/Bit* [mA] Maximum permanent current** [A]
      2 -150…360 0,125 80
      1 -300…+720 0,25 120
      0,5 -600…+1440 0,5 130
      0,2 -1500…+3600 1,25 180
      0,1 -3000…+7200 2,5 310

      size (l/w/h): 68x27x15 mm
      the shunts are linked with a copper bar 20x3,5x200 mm
      * indicated for the lowest measuring range
      ** at room temperature (23°C)

    Order code

    <name> - <resistance value> - <L1> - <L2> - <L3>

    name resistance value L1 L2 L3
    HV-I-BF2 2/…/0,1 0 1…5 0


Download - Data Sheet


Distributors of



Contact Us


Address :

Survey No. 143/1/D,
Milkat No. 2450/1,
Village Vadgaon - 412106,
Tal.: Maval, Dist.: Pune,
Maharashtra, India

Office:

+91-7722020796
info@versacontrols.com


Sales:

+91-7447797456
sales@versacontrols.com





© 2019 Versa Controls. All Rights Reserved.
Powered by aplap software