Versa Controls
COMBI-PROBES HV-I/U-PROBES




Click image to zoom

Product Information:

Features
  • HV-LI-I/U – PROBES consist of a voltage- and a current-PROBE
Current measurement
  • The measuring shunt is placed via mounting straps directly into the measuring circuit
  • The protection of the measuring circuit has to be provided by the user
Voltage measurement
  • Measurement via a voltage divider to reduce the input voltage to an allowed voltage level for the modules
Construction
  • Shunt (type BF1) with mounting straps (temperature range -40...+130°C) and voltage divider
  • Memory device, used for PROBE-identification and calibration data (placed in connector)
  • U-connection-cable = L3 (0,5 m) (heat resistant and high flexible) with loose cable ends
  • Data cable = L2 (1/3/5m) with h8-pin Redel connector
circuit diagram
  • BF1-PROBES


     

    • Current-PROBES (Type BF1)
      Resistor [mΩ] Measuring range [A] Resolution/Bit* [mA] Maximum permanent current** [A]
      2 -150…360 0,125 60
      1 -300…+720 0,25 80
      0,5 -600…+1440 0,5 120
      0,2 -1500…+3600 1,25 150
    • Voltage-PROBES (Type 1000 V)
      Gain Measuring range [V DC] Resolution/Bit [mV/Bit]
      100 0...+/- 37,5 1,25
      50 0...+/- 75 2,5
      24 0...+/- 150 5
      6 0...+/- 600 20
      1 0...+/- 1000 120

    Order code

    <name> - <resistance value> - <L1> - <L2> - <L3>

    name resistance value L1 L2 L3
    HV-I/U-BF1 2/…/0,2 0 1/3/5 0,5
  • BF2-PROBES


     

    • Current-PROBES (Type BF2)
      Resistor [mΩ] Measuring range [A] Resolution/Bit* [mA] Maximum permanent current** [A]
      2 -150…360 0,125 80
      1 -300…+720 0,25 120
      0,5 -600…+1440 0,5 130
      0,2 -1500…+3600 1,25 180
      0,1 -3000…+7200 2,5 310
    • Voltage-PROBES (Type 1000 V)
      Gain Measuring range [V DC] Resolution/Bit [mV/Bit]
      100 0...+/- 37,5 1,25
      50 0...+/- 75 2,5
      24 0...+/- 150 5
      6 0...+/- 600 20
      1 0...+/- 1000 120

    Order code

    <name> - <resistance value> - <L1> - <L2> - <L3>

    name resistance value L1 L2 L3
    HV-I/U-BF2 2/…/0,1 0 1/3/5 0,5


Download - Data Sheet


Distributors of



Contact Us


Address :

Survey No. 143/1/D,
Milkat No. 2450/1,
Village Vadgaon - 412106,
Tal.: Maval, Dist.: Pune,
Maharashtra, India

Office:

+91-7722020796
info@versacontrols.com


Sales:

+91-7447797456
sales@versacontrols.com





© 2019 Versa Controls. All Rights Reserved.
Powered by aplap software