Specifications:

Input Channels

1/2/3/4/5/6/7/8  LVDT

Applications

Standard

Interface  to Fanuc controller O-i / Power Mate / 16 / 18 Series for auto offset correction (Optional)

Interface to Siemens CNC controller for auto offset correction (Optional)

Dimension Type

Linear/Angular

Resolution

0.1µm/ 1µm

Units

mm

Measurement Modes

Current, Min, Max, TIR, AVG

Additional results     

Max, Min, Ovality, and Taper for respective result can be displayed in run mode as additional results.

Result Formula Editor

Result formula can be edited for combinations of LVDT channels and / or other results.

Indications             

Pass, Fail, Warning with facility to select require display reading in require colour according to the tolerance band

Grade

Max 25 Grades ava ilable

Other Features       

Machine Stop Message and Machine stop signal available for reject job condition

Calibration

Single/Double Master configurable

Calibration

Force Mastering after N number of measured jobs.

Group Calibration for selected result in one group.

Auto Mastering is available. Accept Higher and Lower master on inserting into fixture/plug automatically in calibration process

Measurement process

Auto Cycle (After inserting job in Fixture/Plug it will show related Fixture/Plug result)

Measurement Cycle (Sequential measurement)

Charts                       

XBar- R Chart/ XBar- S Chart

Histogram

Runchart

Online SPC

Cp, Cpk, Pp, Ppk, Sigma

Counters

Over Size

Under Size

OK

Not Good

Total measure

Total produce (After receiving Cycle complete signal from Machine using digital input signal)

Setup

99 nos can be created.

Number Of Results

32

Display    

7” touchscreen Colour LCD display 

Ports        

1. RS-232 for PC communication

2.RS-232 for machine interface (compatible Fanuc o-i Power mate/16/18 series)

USB

USB2.0 Compliant (For Mass Storage Device).

Ethernet

Ethernet for sending reports to server using Client server utility

Digital Outputs 

7 outputs, Isolated, Open collector

Digital Inputs

8 Inputs, Isolated

Display Views   

Digital Readout/ Dial / Run Chart

Memory             

 In built micro SD card of 4GB for data storage (Contact manufacturer for additional storage capacity)

Footswitch interface

Available

Login

Operator and Supervisor login (Limited menu access to operator)

Report Storage

Date/Shift wise data storage

Report Transmission

Ethernet LAN/ WI-FI (Need to purchase WI-FI Dongle)/ USB

Report Format

PDF, CSV, and DFQ (to view in Q-DAS application).

In T7V we can only view PDF format file.

All report is available in Year ->Month->Date->and Setup wise format.


Distributors of



Contact Us


Address :

Survey No. 143/1/D,
Milkat No. 2450/1,
Village Vadgaon - 412106,
Tal.: Maval, Dist.: Pune,
Maharashtra, India

Office:

+91-7722020796
info@versacontrols.com


Sales:

+91-7447797456
sales@versacontrols.com





© 2019 Versa Controls. All Rights Reserved.